Partial List of detectable Volitile Organic Compounds (VOC)
Back to Products Page

  • Ammonia
  • Acetic Acid 
  • Acetone 
  • Acetylene
  • Amyl Alcohol 
  • Benzene
  • Butane 
  • Butyl Alcohol
  • Butyl Formate 
  • Butylamine 
  • Butylene
  • Carbon Tetrachloride 
  • Chloro Benzene 
  • Carbon Monoxide 
  • Chloro Cyclo Hexane 
  • Chloroform 
  • Cyclohexane 
  • Cylohexene 
  • l-Dichloroethane 
  • 1,2-Dichloroethane 
  • Diethly Ketone 
  • Diethylamine 
  • Ethane 
  • Ethyl Acetate 
  • Ethyl Alcohol
  • Ethyl Chloride 
  • Ethyl Cyanide 
  • Ethyl Formate 
  • Ethyl Propionate 
  • Ethylene
  • Ethylene Oxide 
  • Formaldehyde 
  • Formic Acid 
  • Heptane
  • Hexane
  • Iso-Butane 
  • Hexyl Alcohol 
  • Hydrogen Gas 
  • Hydrogen Sulfide 
  • Isopropyl Acetate 
  • Methane
  • Methyl Alcohol 
  • Methyl Chloride 
  • Methyl Chloroform 
  • Methyl Cyanide 
  • Methyl Ethyl Ketone 
  • Methyl Propyl Ketone 
  • Methylene Chloride 
  • n-Propyl Chloride 
  • Nitroethane
  • Nitromethane 
  • Pentylamine 
  • Pentylene 
  • Propane 
  • Propionaldehyde 
  • Propyl Alcohol 
  • i-Propyl Chloride 
  • Propyl Cyanide 
  • Propyl Formate 
  • Propylamine 
  • Propylene 
  • Tertiary Butyl Alcohol 
  • Tetrachloroethylene 
  • Toluene
  • 1,1,2- Trichloroethane 
  • Trichlorethylene 
  • Triethylamine 
  • Xylene
  •  

    Semi-Volitile Organic Compounds
    This Fact Sheet is presented by the U. S. Environmental Protection Agency, Region III (EPA) to assist in the selection of analytical parameters and the associated Quality Assurance and Quality Control (QA/QC) procedures to be utilized in Phase II Environmental Assessments under the U.S. Environmental Protection Agency (EPA) Brownfields initiative. This fact sheet is presented for informational purposes only, and should not be construed as a federal policy or directive. The Brownfields Coordinator for this region may be reached at 215-814-5000.
    A semivolatile organic compound is an organic compound which has a boiling point higher than water and which may vaporize when exposed to temperatures above room temperature. Semivolatile organic compounds include phenols and polynuclear aromatic hydrocarbons (PAH).
    LIST OF SEMIVOLATILE ORGANIC COMPOUNDS *

    • Phenol
    • Bis(2-chloroethyl)ether
    • 2-Chlorophenol
    • 1,3-Dichlorobenzene
    • 1,4-Dichlorobenzene
    • 1,2-Dichlorobenzene
    • 2-Methylphenol
    • Bis(2-chloroisopropyl)ether
    • 4-Methylphenol
    • n-Nitroso-di-n-propylamine
    • Hexachloroethane
    • Nitrobenzene
    • Isophorone
    • 2-Nitrophenol
    • 2,4-Dimethlyphenol
    • Bis(2-chloroethoxy)methane
    • 2,4-Dichlorophenol
    • 1,2,4-Trichlorobenzene
    • Naphthalene
    • 4-Chloroaniline
    • Hexachlorobutadiene
    • 4-Chloro-3-methylphenol
    • 2-Methlynaphthalene
    • Hexachlorocyclopentadiene
    • 2,4,6-Trichlorophenol
    • 2,4,5-Trichlorophenol
    • 2-Chloronaphthalene
    • 2-Nitroaniline
    • Dimethylphthalate
    • Acenaphthylene
    • 2,6-Dinitrotoluene
    • 3-Nitroaniline
    • Acenaphthene
    • 2,4-Dinitrophenol
    • 4-Nitrophenol
    • 4-Bromophenyl-phenylether
    • Hexachlorobenzene
    • Pentachlorophenol
    • Phenanthrene
    • Anthracene
    • Carbazole
    • Di-n-butylphthalate
    • Fluoranthene
    • Pyrene
    • Butylbenzylphthalate
    • 3,3'-Dichlorobenzidine
    • Benzo(a)anthracene
    • Chrysene
    • Bis(2-ethylhexyl)phthalate
    • Di-n-octylphthalate
    • Benzo(b)fluoranthene
    • Benzo(k)fluoranthene
    • Benzo(a)pyrene
    • Indeno(1,2,3-cd)pyrene
    • Dibenz(a,h)anthracene
    • Benzo(g,h,i)perylene

    * Please note: The list above corresponds to the EPA Contract Laboratory Program (CLP) semivolatile organic list, and is not a complete list of all toxic semivolatile organic compounds. If the site history suggests a semivolatile organic compound may be present which is not on this list, the compound should be included in the requested analysis.
    ANALYSIS METHODS
    Please note that the methods listed below are EPA approved and the most commonly used by EPA and their contractors. However, they are not the only methods for the analysis of semivolatile organic compounds. In addition, these are not drinking water test methods.


    METHOD

    APPLICABLE MATRICES

    EPA 625 or 1625 (1)

    Aqueous

    EPA SW-846 3010 or 3020/8250 or 8270 (2)

    Aqueous

    EPA SW-846 3500 or 3550/8250 or 8270 (2)

    Soil/Sediment & Waste

    EPA CLP Statement of Work 3/90

    Aqueous & Soil/Sediment

    EPA SW-846 8100 or 8310 (2) 610 (1)

    Water and Soil/Sediment for PAH

    EPA SW-846 8040 (2) or 604 (1)

    Water and Soil/Sediment for Phenols

    1. U.S. Environmental Protection Agency (EPA). 1992. Test Methods for Organic Chemical Analysis of Municipal and Industrial Wastewater. Washington, D.C. July.
    2. EPA. 1986. Test Methods for Evaluating Solid Waste. SW-846. Washington, D.C. September.

    COLLECTION MEDIA/VOLUME
    Listed below are the EPA-recommended preservation and holding times as well as suggested glassware.


    MATRIX

    GLASSWARE

    VOLUME

    PRESERVATIVE

    HOLDING TIME

    Soil/Sediment

    8-oz wide mouthed jar

    1 8-oz jar

    ice to 4º C

    14 days

    Aqueous

    32-oz amber bottle

    2 amber bottles

    ice to 4º C

    7 days

    Waste

    8-oz wide mouth jar

    1 8-oz jar

    none required (ice preferred)

    none (try not to exceed 14 days)

    MINIMUM LABORATORY QUALITY CONTROL MEASURES
    The laboratory should have Standard Operating Procedures available for review for the semivolatile organic compound analyses and for all associated methods needed to complete the semivolatile analysis, such as total solids, instrument maintenance, sample handling, and sample documentation procedures. In addition, the laboratory should have a Laboratory Quality Assurance/Quality Control Statement available for review which includes all key personnel qualifications.


    QC TYPE

    FREQUENCY OF ANALYSIS

    ACCEPTABLE LIMITS

    Gas Chromatograph/Mass Spectrometer (GC/MS) Tuning

    Once per day or more frequently if required by method

    See method criteria for acceptable limits

    Initial Calibration

    Prior to analysis of samples (minimum three concentration levels for every compound and an instrument blank)

    % Relative Standard Deviation of Response Factors of ≤ 30 (see method for any allowable variations), and a minimum Response Factor of ≥ 0.05 (see method for calculation)

    Continuing Calibration

    Once per day (mid-level standard containing all compounds) or more frequently if required by method

    % Difference for Response Factor of ≤ 25 (see method for any allowable variations), and a minimum Response Factor of ≥ 0.05 (see method for calculation)

    Method Blank

    Once per extraction batch

    See method for allowable limits

    Internal Standards

    Six per sample (see method for suggested internal standard compounds)

    -50% to + 100% of Daily standard area and retention time shift (limits depend if packed or capillary column, see method)

    Matrix Spike/Matrix Spike Duplicate

    One set of MS/MSD per 20 samples or analysis set

    See method for allowable limits

    Surrogate Spikes

    Added to each sample (see method for suggested surrogate compounds)

    Report recovery

    MINIMUM DATA PACKAGE REQUIREMENTS

    • Sample results in a tabular form (if soil or sediment) reported on a dry weight basis.
    • Report % moisture or % solids for all soil and sediment samples.
    • Report sample volumes or weights, as well as any dilution factors, for each sample analysis.
    • Return copy of the chain of custody form sent with the samples with laboratory receipt acknowledgment, and the internal or laboratory chain of custody forms.
    • Method blank results.
    • GC/MS tuning data summary.
    • GC/MS initial and continuing calibration data summary forms.
    • GC/MS internal standard data for samples and associated daily standard.
    • Surrogate spike recoveries, either on a separate table or with the results, including laboratory QC limits.
    • Matrix spike recovery tables, including laboratory recovery and relative percent difference QC limits.
    • Date samples were analyzed, on a separate sheet, tune sheet, or results page.
    • Optional: sample, standard and blank chromatograms, quantitation sheets, mass spectra, instrument run logs, and total solids logs.
    Note: The optional QC must be maintained by laboratory for at least one year for possible future QC audits

    Back to Products Page